Evaluation of analytical method for determination of tetracyclines in their dosage forms by HPLC using different types of chromatographic stationary phases (RP-C8 and RP-C18)

Document Type : Original researches

Abstract

Antibiotics are extensively used in animal husbandry practices for the treatment of diseases. Four tetracyclines are commercially available as veterinary medicines, of which oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), and doxycycline (DOX). In the present investigation, a novel simple, sensitive, and inexpensive method of analysis was verified for tetracyclines by RP-HPLC system in bulk drug substance and pharmaceutical forms via two stationary phases (C8 & C18). The separation was attained on a 250 mm column length, 4.6 mm internal diameter, 5 µm particle size, C18 and C8 columns with a (55:25:20) 5% glacial acetic acid: acetonitrile: methanolic acid as elution solution at a 355 nm wavelength. The method was performed at a 0.8 ml/min flow rate. This method was applied without an extraction process. The method was validated following ICH and USP guidelines. It was proved to be reproducible and more economical due to the short retention time of less than 6 min by C8 column and 8 min by C18 column which enabled analysis of tetracycline pharmaceutical products with a relatively lower volume of mobile phase. The result of formulation analysis was statistically validated with a high recovery percentage. Furthermore, the developed method was free from the interference of excipients used in the formulation. The validated method was accurate, precise, linear, and reproducible. The data suggest the possibility of using the method in quality control laboratories with better routine analysis of tetracyclines in their dosage forms.

Keywords

Main Subjects


INTRODUCTION

Antibiotics are extensively used in animal husbandry practices for the treatment and diseases (Moudgil et al. 2019).Tetracyclines are synthetic antibiotics, highly active against a varied range of Gram-negative and Gram-positive microbes. Four tetracyclines are commercially available as veterinary medications, of which oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), and doxycycline (DOX); their chemical structures showed in figure 1. This group of antibiotics is most commonly used for therapeutic purposes in veterinary practice due to their low cost, easy over-the-counter availability, and broad-spectrum (Martins et al. 2015, Prado et al. 2015, and Jank et al.2017).

 

Figure (1): Chemical structure of tetracyclines (Liu et al. 2018)

A lot of techniques have been described for tetracyclines determination in various biological matrices and pharmaceutical preparations. While the official methods of assay retain the microbiological approach (British Pharmacopeia 1993; United State Pharmacopeia 1995), these techniques are lacking of specificity as they are not distinguish between different types of antibiotics leading to false-negative or false-positive results. A further problem of the bioassay is that the degradation products or contaminants of tetracyclines, as epi-, anhydro-, and epianhydro- tetracyclines, which are present in varying amounts in the raw materials and finished products of tetracyclines, may also have antimicrobial properties. Thus the results of bioassay won’t necessarily be a true representation of the antimicrobial potency of the labeled material. Under abnormal environmental conditions (heat, pH, humidity, and light), tetracyclines undergo reversible epimerization at C-4 to form a mixture of epi-, anhydro-, epianhydro and tetracyclines. The epimer has antibiotic activity only 2–5% of that of the parent tetracycline. These degradation products, especially the epianhydro-tetracyclines shown definite toxicity to renal tubular function and initiate a reversible Fanconi-Type syndrome, characterized by polyuria, polydipsia, vomiting, proteinuria, aminoaciduria, and acidosis (Pena et al. 1998). From this viewpoint and owing to the toxicity and probable inactivity of the impurities and degradation products, it is very important to determine tetracyclines in dosage forms simply and precisely.

Recently, new techniques are applied instead of the traditional biological assay, high-performance liquid chromatography (HPLC) to achieve the sensitivity, specificity, and reproducibility for identification and quantification of tetracyclines in its pharmaceutical products. Few reverse-phase high-performance liquid chromatographic (RP-HPLC) methods were reported for the estimation of tetracyclines (Bryan and Stewart 1994, Kazemifard and Moore 1997, Moreno-Cerezo et al. 2001, and Hussien 2014).

In this paper, the LC method for analysis of selected tetracyclines in bulk drug substance and dosage forms using two different types of stationary phases (C8 and C18) are described and validated. This method is applicable for combination use and has been shown to identify oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), and doxycycline (DOX).

MATERIAL AND METHODS

Chromatography (instrumentation and conditions):

The HPLC system consists of a quaternary pump, model 1200, an autosampler injector, and a UV-Vis detector (Agilent). The chromatographic conditions (Ruz et al. 2004) were illustrated in table (1) and quantitative analysis was performed and calculated from the area under curves extrapolated automatically by the software.

Table 1: Chromatographic conditions

Mobile phase

5% glacial acetic acid: acetonitrile: methanol (55:25:20)

Flow rate

0.8 ml/min.

Injection volume

10 µl

Column type

LiChrospher C8 and C18 (250 mm, 4.6 mm i.d., 5 µm particle size)

Column temperature

35oC

Stop  time

10minutes

UV- detector

355 nm

Chemical reagents:

Glacial acetic acid, water, acetonitrile, and methanol of HPLC grade (Honeywell Co, Germany).

The reference standards are Oxytetracycline hydrochloride (100%), Tetracycline hydrochloride (97.1%), Chlortetracycline hydrochloride (102.2%), and Doxycycline hydrochloride (85.7% as doxycycline base); USP reference standards, obtained from Twinbrook Pkwy, Rockville, MD, USA.

Pharmaceutical products containing OTC-HCL (Spectropan® 5% injectable solution), DOX-HCL (DOXIN® 20% water soluble powder), and CTC-HCL (Chloracline® 20% water soluble powder) were obtained from PHARMA SWEDE Co.; TC-HCL (Tetracyclin® WSP Vet 5% water soluble powder) from MSD Animal Health Co.

Standard preparation:

Stock solutions of OTC, TC, CTC, and DOX were prepared by dissolving 10 mg of each compound up to 10 ml methanol to obtain (1 mg/ml for OTC-HCL, 0.97 mg/ml for TC-HCL, 1.022 mg/ml for CTC-HCL and 0.857 mg/ml for DOX-base).

The intermediate solution is prepared by taking 1 ml from stock solution up to 10 ml of the mobile phase.

The working solutions were set by taking 20, 50, 100, 200, and 500 µl from intermediate standard solution up to 1ml of the mobile phase to give a sequence of working solutions that should be freshly prepared. The quality control sample concentrations are 10, 9.7, 10.22, and 8.57µg/ml for OTC-HCL, TC-HCL, CTC-HCL, and DOX-base; respectively.

Calibration plots:

The linearity was achieved over the range of (2–50; 1.94-48.5, 2.044-51.1, and 1.714-42.85 µg/ml for OTC-HCL, TC-HCL, CTC-HCL, and DOX-base in progress). Calibration curves were freshly prepared (triplicate injection for each level) and estimation of the amount of the analytes in samples was interpolated from these curves.

Drug preparation:

The pharmaceutical products are prepared by dissolving an accurate amount of drug in methanol to obtain a solution at a concentration of (1 mg/ml); then make variable dilutions in the mobile phase.

Validation of HPLC assay:

Ideal validation features which should be considered are Linearity and Range, Accuracy (standard addition), Precision (Repeatability, Intermediate Precision), Specificity, Detection Limit (DL), Quantitation Limit (QL), Robustness, and System suitability testing (SST) (ICH 2005 and USP 2019).

 

Linearity and range:

Linearity should be established across the range of the analytical procedure. It appears to be a linear relationship, test results should be proven by appropriate statistical methods (e.g., by calculation of a regression equation and correlation coefficient) to estimate the degree of linearity. The correlation coefficient, the regression line slope, and y-intercept should be determined. The use of at least five concentrations for the establishing of linearity is recommended by ICH.

Accuracy (Standard addition):

Accuracy is calculated as recovery percentage by assaying the known added amount of the analyte in the drug at 3 levels (50, 100, and 150%) by triple injection.

Precision:

The analytical procedure precision is typically expressed as the relative standard deviation (RSD %) of a sequence of measurements. It may be a measure of the degree of frequency (interday precision) or the average accuracy that expresses variances within the laboratory, as is the case on different days (interday precision), or with different persons in the same laboratory.

Precision should be evaluated using at least nine determinations cover the stated range of procedure (i.e., three different levels and triplicates for each level).

Specificity:

In the case of analysis, proof of specificity requires that it can be demonstrated that the assay is not affected by the occurrence of impurities or excipients. Practically, this can be done by fortifying the drug or product substance with appropriate concentrations of impurities or excipients and demonstrating that the result of the examination is not affected by the presence of these foreign substances.

Detection and quantification limits (DL and QL):

DL is determined by analyzing samples with known quantities of the analyte and determining the lowest level at which the analyte can be dependably detected; It was determined using the SD deviation (S) of the intercept and the slope (a) of the lowest concentrations of a standard plot. [DL = 3.3 * S / a; QL = 10 * S / a).

 

Robustness:

Robustness may be determined during the development of the analytical procedure to ensure the ability of liquid chromatography assay to stand up to slight variations in chromatographic conditions as the wavelength (± 2 nm), column temperature (± 2°C), and mobile phase composition; the following adjustment limits apply to minor components of the mobile phase (specified at 50% or less). The quantity of these constituents can be attuned by ±30% relative. Nevertheless, the variations in any constituent cannot exceed ±10% absolute (to the total mobile phase), consequently, mixture ranges of 47.5:32.5:20 – 62.5:17.5:20 or 61:25:14 – 49:25:26 while the original mixture is 55:25:20 (USP 2019).

System suitability testing (SST):

System suitability testing is run every time a method is used either before or during analysis. The results of each system suitability test are compared with defined acceptance criteria and if they pass, the method is deemed satisfactory on that occasion. The primary SST parameters considered are retention time (tR), theoretical plate number of column (N), and tailing factor (Tf).

STATISTICAL ASSESSMENT:

The obtained results were analyzed using SPSS Inc., version 22.0, Chicago, IL, USA to calculate mean, standard deviation (SD), and relative standard deviation (RSD) (Morgan et al. 2019).

RESULTS

Linearity and range:

Linearity results for both columns are illustrated in table (2) and figure (2-5) showing that an excellent correlation between the analyte concentration and the peak area.

 

 

 

 

 

 

Table 2: Results of linearity and range

Parameters

Column

OTC

TC

CTC

DOX

Linearity range (µg/ml)

 

2.00- 50.0

1.940- 48.50

2.044- 51.10

1.714- 42.85

Correlation coefficient

C8

0.9999

0.9999

0.9997

0.9993

C18

0.9999

0.9999

0.9999

0.9997

Slope

C8

6.2173

4.528

1.509

4.6455

C18

6.4937

4.8007

1.696

5.3587

Intercept

C8

0.0292

0.6003

0.2703

2.2023

C18

- 0.2041

- 0.2939

0.127

1.877

 

Figure (2): Calibration curves of OTC-HCL using C8 & C18 columns

 

Figure (3): Calibration curves of TC-HCL using C8 & C18 columns

 

Figure (4): Calibration curves of CTC-HCL using C8 & C18 columns

 

Figure (5): Calibration curves of DOX-HCL using C8 & C18 columns

Accuracy:

The percentage recoveries for both columns were analyzed and tabulated in table (3).

Table (3): Results of accuracy (%)

Level (%)

Column

OTC

TC

CTC

DOX

Acceptance criteria

50

C8

98.7

99.1

99.1

99.3

98- 102 %

C18

99.5

99.2

98.8

99.5

100

C8

100.1

101.5

100.5

100.01

C18

100.5

100.2

101.1

100.1

150

C8

101.1

99.1

101.2

100.4

C18

101.2

98.7

99.05

101.1

Precision:

The results of precision are summarized in table (4). Relative standard deviations (RSD) were calculated and assured that both columns were found to be precise. The Intra-day Precision ranged from 0.51- 0.92 % and the Intermediate Precision ranged from 0.8- 1.6 % for all tested compounds.

Table (4): Results of precision (RSD %)

Parameters

Column

OTC

TC

CTC

DOX

Acceptance criteria

Repeatability (Intra-day Precision)

C8

0.74

0.61

0.82

0.55

≤ 1%

C18

0.71

0.92

0.66

0.51

Intermediate Precision

Inter-day Precision

C8

0.82

0.81

0.94

0.89

≤ 2%

C18

0.9

0.88

1.2

1.1

Different persons

C8

1.2

1.4

1.1

1.6

≤ 2%

C18

0.8

1.1

0.92

1.5

Specificity:

As shown in fig (6-9), HPLC Chromatograms of four tetracyclines pure standard at a concentration of QC and their dosage forms at a concentration of QC. No matrix interferences were observed on the intended chromatograms at the same retention time (TR).

 

Figure (6): Chromatograms of OTC-HCL (10µg/ml) in pure [A] and dosage [B] forms

 

Figure (7): Chromatograms of TC-HCL (9.7µg/ml) in pure [A] and dosage [B] forms

 

Figure (8): Chromatograms of CTC-HCL (10.22µg/ml) in pure [A] and dosage [B] forms

 

Figure (9): Chromatograms of DOX-base (8.57µg/ml) in pure [A] and dosage [B] forms

DL and QL:

The DL and QL values were summarized in table (5); the obtained results indicate that the developed method is sensitive.

Table (5): Results of DL and QL (µg/ml)

Parameters

Column

OTC

TC

CTC

DOX

DL

C8

0.13

0.05

0.25

0.25

C18

0.09

0.03

0.19

0.15

QL

C8

0.38

0.16

0.76

0.76

C18

0.26

0.09

0.56

0.46

Robustness:

The robustness results are summarized in table (6). Small changes in the chromatographic conditions have no significant effect on the peak area of the peak of specified drugs. Hence, the developed method was found to be robust.

 

Table (6): Results of robustness (RSD %)

Altered condition

Column

OTC

TC

CTC

DOX

Acceptance criteria

Column temperature

C8

0.53

0.22

0.26

0.63

≤ 2%

C18

0.35

0.43

0.42

0.24

Wavelength

C8

1.08

0.37

0.60

0.40

≤ 2%

C18

0.61

0.59

0.48

0.89

Mobile phase composition

C8

1.47

0.58

0.48

1.02

≤ 2%

C18

0.96

0.50

0.65

0.93

Pooled RSD%

C8

1.03

0.51

0.53

0.82

≤ 6%

C18

0.65

0.51

0.51

0.75

System Suitability test:

The system suitability test was performed using six replicate injections of standards before analysis of samples. Relative standard deviations of the retention time, tailing factor, and number of theoretical plates were illustrated in table (7).

Table (7): Results of SST (mean ± SD)

Parameters

Column

OTC

TC

CTC

DOX

Acceptance criteria

Retention time (tR)

C8

1.8±0.01

(0.6 %)

3.5±0.01

(0.3 %)

4.0±0.03

(0.8 %)

5.1±0.04

(0.8 %)

RSD ≤ 1%

C18

4.3±0.01

(0.2 %)

5.1±0.03

(0.6 %)

6.5±0.02

(0.3 %)

7.5±0.02

(0.3 %)

Tailing factor (Tf)

C8

1.1±0.01

1.2±0.01

1.2±0.01

1.1±0.04

Tf ≤ 2

C18

1.1±0.03

1.1±0.003

1.4±0.01

1.1±0.03

Theoretical plates (N)

C8

4558±91

9151±80

6580±172

9050±81

N ˃ 2000

C18

13187±154

12086±178

10101±88

10098±172

DISCUSSION

Excellent separation of four tetracyclines (oxytetracycline (OTC), tetracycline (TC), chlortetracycline (CTC), and doxycycline (DOX)) was achieved, and no overlapping peaks were detected using two stationary phases (RP-C8 & RP-C18). The calibration plots were linear; the relationship between concentration and peak area shows its suitability in an in-vitro investigation. The method precision and accuracy were found to be satisfactory. The results of this study were acceptable and the method was robust to be stable against slight changes in the chromatographic conditions.

The linearity was developed at five concentration levels. The prepared standard solutions were freshly prepared before injection into HPLC system as tetracyclines are highly affected by variations in temperature, time, humidity, light (Okerman et al. 2007, Berendsen et al. 2011). The correlation coefficient was greater than 0.999 recommended by ICH (2005). The obtained results of accuracy indicate that the developed assay was found to with high recovery for both columns was found to be in the range of 98.7-101.5 % which was within the acceptable range set by ICH (2005). It was proved to be reproducible and more economical due to the short retention time retention time of less than 6 min by C8 column and 8 min by C18 column which enabled analysis of tetracycline pharmaceutical products with a relatively lower volume of mobile phase. There were no interferences of excipients in the examined pharmaceutical products; consequently extraction and purification are not required to be analyzed (Sivakumar et al. 2007).

This is in line with the theory of green analytical chemistry which is part of the concept of sustainable development. The miniaturization of analytical devices and shortening of the time elapsed between conducting analysis and obtaining reliable analytical results are important aspects of green analytical chemistry. Solventless extraction techniques and the application of alternative solvents are considered to be the main approaches complying with green analytical chemistry principles (Tobiszewski et al. 2010).

The results of the study of the two columns are close together with slight differences in retention time as the four tetracyclines were separated approximately two minutes earlier by column RP-C8 from RP-C18. This is because column C8 is less hydrophobic, and has a lower density, but column C18 is more hydrophobic and has a higher density. Therefore, column C8 has less retention time (Gritti et al. 2019).

CONCLUSION

In the current investigation; a new simple, sensitive and economical analytical method for tetracyclines has been developed with RP-HPLC technology. The developed RP-HPLC method has been validated for accuracy, precision, linearity, and reproducibility following ICH and USP guidelines. Studies indicate that the developed methods were free from the interference of excipients used in the preparation. The limits of detection and the low quantities achieved indicate that the method is very sensitive. The data suggest the possibility of using the method in quality control laboratories and routine analysis of tetracyclines in their dosage forms using RP-C8 & RP-C18.

Berendsen BJA, Elbers IJW, Stolker AAM. 2011. The stability of antibiotics in matrix and reference solutions determined using a straight-forward procedure applying mass spectrometric detection. Food Addit Contam Part A; 28(12): 1657-66.
British Pharmacopoeia, BP, HMSO, London, 1993
Bryan PD, Stewart JT. 1994. Chromatographic analysis of selected tetracyclines from dosage forms and bulk drug substance using polymeric columns with acidic mobile phases. J. Pharm. Biomed. Anal.; 12: 675-92
Gritti F, Hlushkou D, Tallarek U. 2019. Faster dewetting of water from C8-than from C18-bonded silica particles used in reversed-phase liquid chromatography: Solving the paradox. J. Chromatogr. A, 1602: 253-65.‏
Hussien EM. 2014. HPLC method validation for modernization of the tetracycline hydrochloride capsule USP monograph. Bulletin of Faculty of Pharmacy, Cairo University, 52(2): 239-44.‏
ICH (International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceutical for Human Use) (2005). Validation of Analytical Procedures: Text and Methodology Q2 (R1).
Jank L, Martins MT, Arsand JB, Motta TMC, Feijó TC, dos Santos Castilhos T, Hoff RP, Barreto F, Pizzolato TM 2017. Liquid chromatography–tandem mass spectrometry multiclass method for 46 antibiotics residues in milk and meat: development and validation. Food Anal. Methods, 10(7): 2152-64.
Kazemifard AG, Moore DE. 1997. Evaluation of amperometric detection for the liquid chromatographic determination of tetracycline antibiotics and their common contaminants in pharmaceutical formulations. J. Pharm. Biomed. Anal.; 16: 689-96.
Liu F, Zhang X, Li Y, Gao H, Ling P, Li X, Chen O, Ma A, Shao A, Li M, Wang F. 2018. Simultaneous screening and determination of eight tetracycline antibiotics illegally adulterated in herbal preparations using HPLC–DAD combined with LC–MS–MS. Chromatographia, 81(2): 303-14.
Martins MT, Barreto F, Hoff RB, Jank L, Arsand JB, Feijó TC, Schapoval EES. 2015. Determination of quinolones and fluoroquinolones, tetracyclines and sulfonamides in bovine, swine and poultry liver using LC-MS/MS. Food Additives and Contaminants: Part A, 32(3): 333-41.‏
Moreno-Cerezo JM, Córdoba-Dıaz M, Córdoba-Dıaz D, Córdoba-Borrego M. 2001. A stability study of tetracycline and tetracycline cyclodextrins in tablets using a new HPLC method. Journal of pharmaceutical and biomedical analysis, 26(3): 417-26.‏
Morgan GA, Barrett KC, Leech NL, Gloeckner GW. 2019. IBM SPSS for introductory statistics: Use and interpretation. Routledge.
Moudgil P, Bedi JS, Aulakh RS, Gill JPS, Kumar A. 2019. Validation of HPLC multi-residue method for determination of fluoroquinolones, tetracycline, sulphonamides, and chloramphenicol residues in bovine milk. Food Analytical. Methods, 12(2): 338-46.
Okerman L, Van Hende J, De Zutter L. 2007. Stability of frozen stock solutions of beta-lactam antibiotics, cephalosporins, tetracyclines and quinolones used in antibiotic residue screening and antibiotic susceptibility testing. Anal Chim Acta.: 586-284.
Pena A, Carmona A, Barbosa A, Lino C, Silveira I, Castillo B. 1998. Determination of tetracycline and its major degradation products by liquid chromatography with fluorescence detection. J Pharm Biomed Anal., 18(4-5): 839-45.‏
Prado CK, Ferreira FD, Bando E, Machinski Jr M. 2015. Oxytetracycline, tetracycline, chlortetracycline and doxycycline in pasteurised cow’s milk commercialised in Brazil. Food Addit. Contam. Part B, 8(2): 81-4.‏
Ruz N, Zabala M, Kramer MG, Campanero MA, Dios-Vieitez MC, Blanco-Prieto MJ. 2004. Rapid and simple determination of doxycycline in serum by high performance liquid chromatography application to particulate drug delivery systems. J. Chromatogr. A; 1031(1-2): 295-301.
Sivakumar T, Manavalan R, Muralidharan C, Valliappan K. 2007. Multi-criteria decision making approach and experimental design as chemometric tools to optimize HPLC separation of domperidone and pantoprazole. J Pharm Biomed Anal, 43(5): 1842- 8.‏
Tobiszewski M, Mechlińska A, Namieśnik J. 2010. Green analytical chemistry-theory and practice. Chem Soc Rev, 39(8): 2869-78.‏
United States Pharmacopoeia XXIII, United States Pharmacopoeial Convention, Rockville, MD, USA, 1995.
USP 2019. Validation of Compendial Procedures and Chromatography. Rockville, Rockville, MD: United States Pharmacopeia.